All Products
Showing 433–450 of 1040 results
Embedded Antenna Designs - 4G Pentaband Antenna
XProduct SKU: FPTR35211-SM-KR-P
The PTR7210 is a ½ wave dipole blade antenna covering 700/800/900/1800 and 2100 MHz for LTE, Cellular, GSM and UMTS (3G) operation. It has a injection-moulded cover and comes with SMA-Male swivel joint connector that can lock in three positions. The PTR27210 offers a gain of 0 dBi.The PTR7210 is an ideal solution for LTE and penta-band cellular applications including wireless routers, telemetry and telematics where comprehensive LTE, cellular, GSM and 3G capability is required
CONTACT US FOR VOLUME PRICING
Enquire for availability
Make an EnquiryEmbedded Antenna Designs - 4G Pentaband Antenna
XProduct SKU:
Enquire for availability
Make an EnquiryEmbedded Antenna Designs - GSM Dual Band Antenna
XProduct SKU:
GSM Dual Band Antenna Stubby Type Right Angled FME Female
CONTACT US FOR VOLUME PRICING
Enquire for availability
Make an EnquiryEmbedded Antenna Designs - RF 2.4 /5.8GHz Antenna
XProduct SKU:
RF 2.4 /5.8GHz Antenna Screw Mount with 2m Cable SMA Male
CONTACT US FOR VOLUME PRICING
Enquire for availability
Make an Enquiryembedded pc
XProduct SKU: SXM-256GB-MINIPC-W-P
Overview coming soon - Call 01527 830800 for information
Specifications
Mini PC Intel Gemini Lake upto 2.7GHz 8GB DDR4, 128GB to 1TB SSD Wifi & BT 4.2 UHD Graphics x2 USB 3 / HDMI / SD card Power USB-C 12V /2AFrom£190.00 (Ex. VAT)
Enquire for availability
Make an EnquiryExcelitas - C30902SH
XProduct SKU: C30902SH-P
Excelitas C30902SH
General Description The C30902SH is avalanche photodiode selected for low noise fabricated with a double-diffused “reach-through” structure. This structure provides high responsivity between 400 and 1000 nm as well as extremely fast rise and fall times at all wavelengths. The responsivity of the device is independent of modulation frequency up to about 800 MHz. The detector chip is hermetically-sealed behind a flat glass window in a modified TO-18 package. The useful diameter of the photosensitive surface is 0.5 mm. 0.475mm photosensitive diameter, dead time filter 20ns, photon detection efficiency >70% at 700nm Applications Single molecule detection High throughput single photon experiments LIDAR Photon correlation spectroscopy Astronomical observation Optical range finding Adaptive optics Ultra sensitive fluorescence Particle sizingCONTACT US FOR VOLUME PRICING
Enquire for availability
Make an EnquiryExcelitas - Dual-Element Pyrodetectors
XProduct SKU: PYD1388/7083-P
This Pyrodetector Series represents Excelitas standard analog Pyrodetector offering. Our PYD 1388 (replacement to LHi 878) and PYD 1398 (replacement to LHi 968) Dual-Element Pyrodetectors feature two elements configured in a series connection with an FET in source-follower circuit. They are integrated into a robust TO-5 Metal Housing with an optical window
Features
- TO-5 metal housing for EMI shielding - High responsivity ceramic pyroelectric elements - Dual detector with 2 × 1 mm2 elements - 95°/100° field-of-view - Integrated FET in source follower configuration - Integrated EMI filtering stageSpecifications
- Responsivity: 4.2 kV/W (typical) - Noise: 20µVpp (typical) / 50µVpp (max) - Operation requirements: 2.0-10V - Housing with optical window: TO-5 - PYD 1388 Field-of-View (horiz/vert): 95°/87° - PYD 1398 Field-of-View (horiz/vert): 100°/100° - PYD 1388 with 1 EMI filtering stage - PYD 1398 with 2 EMI filtering stagesCONTACT US FOR VOLUME PRICING
5755 In stock
Make an EnquiryExcelitas - Gas Detectors
XProduct SKU: PYS 3228 TC G1/G20-3641-P
Single-Element Pyroelectric Detectors are often applied for temperature and gas measuring applications in one-channel or dual-channel variants, which is then one output per element. Single-Element variants are offered as thermally compensated devices. The principle of Gas monitor application is called NDIR. NDIR requires Detectors with narrow-band optical filters. Excelitas provides a range of suited filter windows for those gases which show an absoption band in the IR spectral range.
CONTACT US FOR VOLUME PRICING
Enquire for availability
Make an EnquiryExcelitas - NIR Single-Photon Counting Module SPCM NIR
XProduct SKU: SPCM-NIR-10-FC
NIR-Optimized Single Photon Counting Module Excelitas Technologies’ SPCM-NIR is a Single Photon Counting Module specifically selected and performance-optimized for the near infra-red wavelength spectrum. The SPCM-NIR uses a specially selected SLiK silicon avalanche photodiode with peak single photon detection efficiency typically better than 73% while maintaining uniformity over a 180µm diameter active area. This module achieves enhanced red and NIR sensitivity while maintaining such other performance parameters of the standard SPCM-AQRH, such as outstanding uniformity, overload protection, temperature stability and linearity. This NIR spectrum enhanced device is designed to support long range LIDAR, quantum communication and microscopy, as well as many other applications. Excelitas’ series of photon counting modules are designed and built to be fully compliant with the European Union Directive 2015/863/EU – Restriction of Hazardous Substances in Electrical and Electronic equipment (RoHS). Applications * LIDAR * Quantum Cryptography * Photon correlation spectroscopy * Astronomical observation * Optical range finding * Adaptive optics * Ultra-sensitive fluorescence * Particle sizing * Microscopy and imaging
Features
* Peak photon detection efficiency (PDE) @ 780nm: 70% typical * Active area: 180 µm * Gated output * Single +5 V supply * RoHS-compliant * Linearity over high count rateCONTACT US FOR VOLUME PRICING
Enquire for availability
Make an EnquiryExcelitas - Single-Output Quad Pyros
XProduct SKU: PYQ1348/3596-P
PYQ 1398, PYQ 1348 Single-Output Quad Pyros Excelitas' PYQ 1348 and PYQ 1398 Pyrodetectors provide four sensing elements in a geometric square placement. Electrically all elements are connected in series, forming one analog output signal. The two versions vary from each other by different window size and element spacings. This "Quad" Pyrodetector Series provides all four elements connected to one common output. All elements are electrically connected to one FET in source follower connection forming one analog output signal. Two different window options are provided: Rectangular window or square window size. Different geometrical placements are available on request. When being applied with suitable lens or mirror optics these detectors are used in ceiling mount devices. The PYQ 1348 is also available with smaller elements of 0.8x0.8 mm². Small elements are suitable for compact lenses and short detection distances.
Features
- TO-5 metal housing for EMI shielding - High-responsivity ceramic pyroelectric elements - Quad detector with 1 × 1 mm² (0.8 x 0.8 mm²) elements - 124° (140°) Field-of-view (PYQ 1348) - 103° Field-of-view (PYQ 1398) - Integrated FET in source follower configuration - Integrated EMI filtering stage Applications Mid (short)-distance motion detection (with lens) Energy saving applications Intrusion alarms Ceiling mounted applicationsSpecifications
- Responsivity: 6.5 (10.2) kV/W (typical) - Noise: 40 (60) µVpp (typical) / 100 (200) µVpp (max) - Operation requirements 2.0 -10 V - Housing with optical window: TO-5 - PYQ 1398 Field-of-view (horiz/vert): 103°/100° - PYQ 1348 Field-of-view (horiz/vert): 124°/124° (140°/140°)CONTACT US FOR VOLUME PRICING
Enquire for availability
Make an EnquiryExcelitas C30659 Series - 900/1060/1550/1550E
XProduct SKU: C30659-1550E-R2AH-P
Excelitas C30659 Series - 900/1060/1550/1550E
Si and InGaAs APD Preamplifier Modules Excelitas Technologies’ C30659 Series includes a Si or InGaAs Avalanche Photodiode (APD) with a hybrid preamplifier, in the same hermetically-sealed TO-8 package, to allow for ultra-low noise operation. The Si APDs used in these devices are the same as used in Excelitas’ C30817EH, C30902EH, C30954EH and C30956EH products, while the InGaAs APDs are used in the C30645EH and C30662EH products. These detectors provide very good response between 830 and 1550 nm and very fast rise- and fall-times at all wavelengths. The preamplifier section of the module uses a very low noise GaAs FET front end designed to operate at higher transimpedance than Excelitas’ regular C30950 Series. Excelitas’ InGaAs C30659-1550E Preamplifier Modules, with 1550 nm peak response, are designed to exhibit higher damage thresholds, thus providing greater resilience when exposed to high optical power densities. Customization of the C30659 Series of APD Preamplifier Modules is available to meet your specific design challenges; modifications include bandwidth and gain optimization, use of different APDs, FC-connectorized packaging. Applications - LIDAR - Range finding - Laser designation - Confocal microscopy - High-speed, extreme low-light detection - Distributed temperature sensing (DTS) - Analytical instrumentation - High-speed, free-space optical communicationFeatures
- System bandwidths of 50 and 200MHz - Ultra low noise equivalent power (NEP) - Spectral response range: o With Si APD: 400 to 1100 nm o With InGaAs APD: 1100 to 1700 nm - Typical power consumption: 150 mW - ±5 V amplifier operating voltages - 50 ? AC load capability (AC-Coupled) - Hermetically-sealed TO-8 package - High reliability - Fast overload recovery - Pin-to-pin compatible with the C30950 - Light entry angle, over 130° - Model 1550E exhibits enhanced damage threshold - RoHS-compliantCONTACT US FOR VOLUME PRICING
Enquire for availability
Make an EnquiryExcelitas Single Photon Counting Module SPCM-AQ4C
XProduct SKU: SPCM-AQ4C-P
Excelitas SPCM-AQ4C
General Description The SPCM-AQ4C is a four-channel photon counting module capable of detecting single photons of light over the wavelength range from 400 nm to 1060 nm. Each channel is independent from the others. Single Photon Counting Module 4 Channel Array The SPCM-AQ4C uses a unique silicon avalanche photodiode (SLiK) that has a circular active area of 180 µm diameter with a peak photon detection efficiency exceeding 60% at 650 nm. Each photodiode is both thermoelectrically cooled and temperature controlled, ensuring stabilized performance despite changes in the ambient temperature. The SPCM-AQ4C module uses an improved circuit with a peak count rate >4M c/s for short bursts of time on all four channels and a count rate of 1.5 M c/s for continuous operation. There is a "dead time" of 50 nanoseconds (ns) between pulses. The module requires +2 Volts, +5 Volt, and +30 Volt power supplies. The output of each channel – a TTL pulse that is 4.5 Volts high (into a 50 O load) and 25 ns wide – is available at the card edge behind the circuit board. Each TTL pulse corresponds to a detected photon. All input and output signals are available at the card connector. Applications Single molecule detection High throughput single photon experiments LIDAR Photon correlation spectroscopy Astronomical observation Optical range finding Adaptive optics Ultra sensitive fluorescence Particle sizingFeatures
Peak photon detection efficiency at 650 nm: 60% typical Afterpulsing probability 0.5% Gated input TTL output FC fiber connector mounted and aligned on each detector Four channels in one package Self-contained APD module with integrated electronics ROHS compliantCONTACT US FOR VOLUME PRICING
Enquire for availability
Make an EnquiryExcelitas Single Photon Counting Module SPCM-AQRH Series
XProduct SKU: SPCM-AQRH-12-FC-P
Excelitas SPCM-AQRH Series
Excelitas newly enhanced SPCM-AQRH Single-Photon Counting Module detects single photons over the wavelength range of 400 nm to 1064 nm with performance parameters superior to other solid state or vacuum-tube based photon counters. Single Photon Counting Module The SPCM-AQRH uses a unique silicon avalanche photodiode (SLiK) with a circular active area, achieving peak photon detection efficiency greater than 70% at 650 nm over a 180 µm diameter, with unmatched uniformity over the full active area. A TTL-level pulse is generated for each photon detected and the signal is available at the BNC connector at the rear of the module. The photodiode is both thermoelectrically cooled and temperature controlled, ensuring stabilized performance despite ambient temperature changes. Operating temperature range has been increased and the module will function with case temperatures between 5°C and 70°C. The module comes as standard with a free-space window to the APD, with FC fiber adapter, C-mount or tube cage mount bracket/adapter options. Recent electronic circuit enhancements have reduced the minimum dead time to less than 25 ns, thereby increasing linearity and improving the dynamic range of the module. Timing resolution of the module was also improved significantly. The SPCM-AQRH has internal protection circuitry that protects the avalanche photodiode and the module electronics from damage due to accidental overload from exposure to ambient lighting. Applications - LIDAR - Quantum Cryptography - Photon correlation spectroscopy - Astronomical observation - Optical range finding - Adaptive optics - Ultra-sensitive fluorescence - Particle sizing - MicroscopyFeatures
- Peak PDE: > 70% @ 650nm - 180µm active area - > 35 Mcps dynamic range - Gated output - Single +5 V supply - RoHS-compliant - Low after pulse probability - High uniformity over large active area - Unmatched linearity - Free space window, FC fiber adaptor, C-mount bracket, Tube cage mount bracket optionsSpecifications
STANDARD SPCM-AQRH-WX OPTION TABLE (ADD -FC FOR REGULAR FC VERSION) | ||||||||||||
Model | Output Pulse Options | X - Maximum Dark Count Rates (cps) | Optical Mounting Bracket (Non FC Module only) |
|||||||||
SPCM-AQRH-WX (-FC)(-BR_) | Output Pulse Width (ns) | Dead Time (ns) | Output Pulse Height (V) | -W0 | -W1 | -W2 | -W3 | -W4 | -W5 | -W6 | -BR1 | -BR2 |
SPCM-AQRH-1X | 10 | 24 | 2.2 | 1500 | 1000 | 500 | 250 | 100 | 50 | 25 | SM1 | C-MOUNT |
SPCM-AQRH-2X | 18 | 28 | 2.2 | 1500 | 1000 | 500 | 250 | 100 | 50 | 25 | SM1 | C-MOUNT |
SPCM-AQRH-3X | 28 | 35 | 2.2 | 1500 | 1000 | 500 | 250 | 100 | 50 | 25 | SM1 | C-MOUNT |
SPCM-AQRH-4X | 10 | 24 | 4.4 | 1500 | 1000 | 500 | 250 | 100 | 50 | 25 | SM1 | C-MOUNT |
SPCM-AQRH-5X | 18 | 28 | 4.4 | 1500 | 1000 | 500 | 250 | 100 | 50 | 25 | SM1 | C-MOUNT |
SPCM-AQRH-6X | 28 | 42 | 4.4 | 1500 | 1000 | 500 | 250 | 100 | 50 | 25 | SM1 | C-MOUNT |
From£3,600.00 (Ex. VAT)
2 In stock
Make an EnquiryEXCELITAS SPCM-780-12-FC SPCM
XProduct SKU: SPCM-780-12-FC
The Excelitas SPCM-NIR is a Single-Photon Counting Module specifically selected and performance-optimized for the near infra-red wavelength spectrum. This NIR spectrum enhanced device is designed to support long range LiDAR, quantum communication and microscopy, as well as many other applications.
CONTACT US FOR VOLUME PRICING
Enquire for availability
Make an EnquiryEXCELITAS SPCM-780-14-FC SPCM
XProduct SKU: SPCM-780-14-FC
The Excelitas SPCM-NIR is a Single-Photon Counting Module specifically selected and performance-optimized for the near-infrared wavelength spectrum. This NIR spectrum enhanced device is designed to support long range LiDAR, quantum communication and microscopy, as well as many other applications.
CONTACT US FOR VOLUME PRICING
Enquire for availability
Make an EnquiryEXCELITAS SPCM-780-44-FC SPCM
XProduct SKU: SPCM-780-44-FC
The Excelitas SPCM-NIR is a Single-Photon Counting Module specifically selected and performance-optimized for the near-infrared wavelength spectrum. This NIR spectrum enhanced device is designed to support long range LiDAR, quantum communication and microscopy, as well as many other applications.
CONTACT US FOR VOLUME PRICING
Enquire for availability
Make an EnquiryEXCELITAS SPCM-800-12-FC SPCM
XProduct SKU: SPCM-800-12-FC
The Excelitas SPCM-NIR is a Single-Photon Counting Module specifically selected and performance-optimized for the near-infrared wavelength spectrum. This NIR spectrum enhanced device is designed to support long range LiDAR, quantum communication and microscopy, as well as many other applications.
CONTACT US FOR VOLUME PRICING
Enquire for availability
Make an EnquiryEXCELITAS SPCM-800-13-FC SPCM
XProduct SKU: SPCM-800-13-FC
The Excelitas SPCM-NIR is a Single-Photon Counting Module specifically selected and performance-optimized for the near-infrared wavelength spectrum. This NIR spectrum enhanced device is designed to support long range LiDAR, quantum communication and microscopy, as well as many other applications.
CONTACT US FOR VOLUME PRICING
Enquire for availability
Make an Enquiry