Durakool Automotive HVDC Contactors

Durakool HVDC Contactors from Solsta
Duralkool

Features
Series CHV20CHV300CHV400CHV500CHV600
Description A magnetic arc blowout HVDC 20A 1500VDC, pre-charge contactor. Oxygen free copper contacts sealed in an inert gas ceramic chamber and industry standard QC terminals. UL Approved.A magnetic arc blowout HVDC 300A 1000VDC contactor with a maximum break current of 2000A. Oxygen free copper contacts sealed in an inert gas ceramic chamber and female M6 power terminals. Auxiliary contact as standard.A magnetic arc blowout HVDC 400A 1500VDC contactor with a maximum break current of 2500A. Oxygen free copper contacts sealed in an inert gas ceramic chamber and female M6 power terminals. Auxiliary contact as standard. Dual coil economiser as standard. UL recognised.A magnetic arc blowout HVDC 500A 1500VDC contactor with a maximum break current of 2500A. Oxygen free copper contacts sealed in an inert gas ceramic chamber and female M6 power terminals. Auxiliary contact as standard. Dual coil economiser as standard. UL recognised.A magnetic arc blowout HVDC 600A 1500VDC contactor with a maximum break current of 2500A. Oxygen free copper contacts sealed in an inert gas ceramic chamber and female M6 power terminals. Auxiliary contact as standard. Dual coil economiser as standard. UL recognised.
Supplier DurakoolDurakoolDurakoolDurakoolDurakool
Dimensions (L x W x H) mm 78 x 40.5 x 48.2 84.5 x 42.5 x 73.5 104 x 70 x 108.1 104 x 70 x 108.1 104 x 70 x 108.1
Contact Configuration SPST-NO-DM SPST-NO-DM SPST-NO-DM SPST-NO-DM SPST-NO-DM
Max. Switching Voltage 1500VDC 1000VDC 1500VDC 1500VDC 1500VDC
Rated Current 20A 300A 400A 500A 600A
Contact Material Oxygen free Copper (Cu) Oxygen free Copper (Cu) Oxygen free Copper (Cu) Oxygen free Copper (Cu) Oxygen free Copper (Cu)
Coil Voltages 12, 24VDC 12, 24VDC 12, 24VDC 12, 24VDC 12, 24VDC
Datasheet DownloadDownloadDownloadDownloadDownload
Enquire Enquire Enquire Enquire Enquire Enquire
Features
Series CHV800CHV800PDEVR01DEVR03DEVR05
Description A magnetic arc blowout HVDC 800A 1000VDC contactor with a maximum break current of 3000A. Oxygen free copper contacts sealed in an inert gas ceramic chamber and male M10 power terminals. Dual coil economiser as standard.A magnetic arc blowout HVDC 800A 1500VDC contactor with a maximum 2000A break current. Oxygen free copper contacts sealed in an inert gas ceramic chamber & standard female M8 power terminals. Auxiliary contacts standard. Dual coil economiser standard. UL approved.An automotive, magnetic arc blowout HVDC 10A 1000VDC, pre-charge Contactor, with a maximum breaking current of 300A. T2+Ag contacts sealed in inert gas and female M4 power terminals.An automotive, magnetic arc blowout, HVDC 30A 1000VDC, pre-charge Contactor, with a maximum breaking current of 300A. T2+Ag contacts sealed in inert gas and female M4 power terminals.An automotive, magnetic arc blowout, HVDC 50A 1000VDC, pre-charge Contactor, with a maximum breaking current of 300A. T2+Ag contacts sealed in inert gas and female M4 power terminals. UL Recognised.
Supplier DurakoolDurakoolDurakoolDurakoolDurakool
Dimensions (L x W x H) mm 145.2 x 66.6 x 132.8 104 x 70 x 108.1 37.2 x 51.3 x 47.8 37.2 x 51.3 x 47.8 37.2 x 51.3 x 47.8
Contact Configuration SPST-NO-DM SPST-NO-DM SPST-NO-DM SPST-NO-DM SPST-NO-DM
Max. Switching Voltage 1000VDC 1500VDC 1000VDC 1000VDC 1000VDC
Rated Current 800A 800A 10A 30A 50A
Contact Material Oxygen free Copper (Cu) Oxygen free Copper (Cu) T2+Ag T2+Ag T2+Ag
Coil Voltages 12, 24VDC 12, 24VDC 12 ~ 48VDC 12 ~ 48VDC 12 ~ 48VDC
Datasheet DownloadDownloadDownloadDownloadDownload
Enquire Enquire Enquire Enquire Enquire Enquire
Features
Series DEVR10DEVR13DEVR20DEVR30DEVR40
Description An automotive, magnetic arc blowout, HVDC 100A 1000VDC Contactor, with a maximum breaking current of 1000A. T2+Ag contacts sealed in inert gas and female M5 power terminals. Auxiliary contact option. UL Recognised.An automotive, magnetic arc blowout, HVDC 135A 1000VDC Contactor, with a maximum breaking current of 1000A. T2+Ag contacts sealed in inert gas and female M5 or M6 power terminals. Coil economiser and auxiliary contact option.An automotive, magnetic arc blowout, HVDC 200A 1000VDC Contactor, with a maximum breaking current of 2000A. T2+Ag contacts sealed in inert gas and female M6 or male M8 power terminals. Coil economiser and auxiliary contact option. Non-polarised (bi-directional) design. An automotive, magnetic arc blowout, HVDC 300A 1000VDC Contactor, with a maximum breaking current of 2000A. T2+Ag contacts sealed in inert gas and female M6 or male M8 power terminals. Coil economiser and auxiliary contact option. Non-polarised (bi-directional) designAn automotive, magnetic arc blowout, HVDC 400A 1000VDC Contactor, with a maximum breaking current of 2000A. T2+Ag contacts sealed in inert gas and female M6 or male M8 power terminals. Coil economiser and auxiliary contact option. Non-polarised (bi-directional) design
Supplier DurakoolDurakoolDurakoolDurakoolDurakool
Dimensions (L x W x H) mm 40 x 53.8 x 59 40 x 53.8 x 59 58.2 x 80.5 x 72.1 58.2 x 80.5 x 72.1 58.2 x 80.5 x 72.1
Contact Configuration SPST-NO-DM SPST-NO-DM SPST-NO-DM SPST-NO-DM SPST-NO-DM
Max. Switching Voltage 1000VDC 1000VDC 1000VDC 1000VDC 1000VDC
Rated Current 100A 135A 200A 300A 400A
Contact Material T2+Ag T2+Ag T2+Ag T2+Ag T2+Ag
Coil Voltages 12 ~ 48VDC 12 ~ 48VDC 12, 24VDC 12, 24VDC 12, 24VDC
Datasheet DownloadDownloadDownloadDownloadDownload
Enquire Enquire Enquire Enquire Enquire Enquire
Features  
Series DHVC150DHVC200   
Description Automotive, magnetic arc blowout, HVDC 150A 1000VDC Contactor, with a max. breaking current of 2000A. Oxygen free copper contacts sealed in inert gas & female (M6) or male (M8) power terminals. Bottom or side mounting options. PWM coil economiser & auxiliary contact optional. UL Recognised.Automotive, magnetic arc blowout, HVDC 500A 1000VDC Contactor, with a max. breaking current of 2000A. Oxygen free copper contacts sealed in inert gas & female (M6) or male (M8) power terminals. Bottom or side mounting options. PWM coil economiser & auxiliary contact optional. UL Recognised.   
Supplier DurakoolDurakool   
Dimensions (L x W x H) mm Depends on mounting style. 80.4 x 60.2 x 72.4 80.4 x 60.2 x 72.4    
Contact Configuration SPST-NO-DM SPST-NO-DM    
Max. Switching Voltage 1000VDC 1000VDC    
Rated Current 150A 200A    
Contact Material Cu10200 Cu10200    
Coil Voltages 9V ~ 36VDC, 32 ~ 95VDC 9V ~ 36VDC, 32 ~ 95VDC or 12VDC, 24VDC, 48VDC    
Datasheet DownloadDownload   
Enquire Enquire Enquire    

« Back to Durakool Contactors

Submit enquiry for Not Set